TKA Lab 2 Pump Head Diaphragm Laboratory Low Noise Vacuum Pump

Short Description:

Overheating protection: each product is equipped with a temperature protection switch, when the internal temperature of the body is too high, it will automatically stop, Such as temperature cooling after starting , to ensure the stability and safety of the syste.


Product Detail

Product Tags

Detail

1, corrosion resistance: Anti-corrosion resistant vacuum pump uses a special diaphragm (diaphragm surface composite PTFE coating) and pump head design, including all joints and pipelines, to ensure that the part in contact with the gas part are imported PTFE material, so it can resist most of the corrosive gas; At the same time the electrical switch and the shell also do corrosion prevention treatment, especially on the transmission mechanism and circuit part of the use of corrosion resistant materials to form a closed space, completely isolated from the outside environment, so that the vacuum pump can not only withstand corrosive medium, but also can be perfectly suitable for corrosive environment, completely solve the problem of chemical corrosion resistance of the vacuum pump.

2, no pollution, no maintenance: diaphragm vacuum pump can achieve complete solvent recovery, eliminate toxic and harmful organic solvent pollution to the environment and the health of the operator and nearby personnel, even if the mixed solvent can also be highly recycled; Diaphragm pump is a dry pump without water and oil, so that the laboratory becomes clean and quiet, the user does not need regular cleaning, pipe change, water change and other maintenance work, diaphragm vacuum pump to achieve 100% maintenance free;

3, low noise, low vibration: corrosion resistant vacuum pump adopts motor direct drive power transmission, no intermediate transmission parts, coupled with the diaphragm low stroke, low noise characteristics, so the product noise can be kept below 70dB.

detail4

Products Parameter

Mode

VB20 VB40 VB60

Reted voltage/frequency

220V/50Hz 220V/50Hz 220V/50Hz

Rated power

120W 240W 375W

Pump head type

Double-stage pump

Limiting vacuum degree

8mbar

Operating vacuum degree

15-20mbar

Maximum Operating pressure

1bar

Maximum flow

20L/min 40L/min 60L/min

The interface specification

10MM 12MM

Medium and ambient temperature

5ºC~40ºC

Ambient relative humidity

<80%

Pump head material

PTFE

Composite Diaphragm material

HNBR+PTFE(Can be custemised accorading to custome requirments)

Valve material

FKM EFPM(Can be custemised accorading to custome requirments)

Vacuum gauge

With vacuum regulating valve without

Working time

Continuous work

Noice

<70dB

Rated ratorating speed

1450RPM 1450RPM 1450RPM

Overall dimension

315*165*210 320*170*210 360*295*225mm

Weight

96kg 11kg 18kg