Hot Air Sterilizer Dry Heat Oven
Materials and features:
1) Temperature control instrument: the product adopts comprehensive electromagnetic compatibility design and humanised menu design, adopts the company's self-developed adaptive temperature control technology for temperature control, making the operation of the equipment completely foolproof, solving the drawbacks of the previous PID control technology that requires multiple parameter adjustments, temperature overshoot, etc., temperature control effect. Dual screen high brightness wide window digital display, the value is clear and intuitive. Microcomputer intelligent control, set the temperature, the instrument controls its own heating power, and display the heating state, temperature control and stability. Over-temperature alarm and automatically cut off the heating power. Timing function, timing time is up to 9999 minutes.
2) Insulation layer: domestic, good performance of the insulation structure. From inside to outside, there are inner cavity, inner shell, ultra-fine glass fibre, aluminium reflective foil sheet, air sandwich, less heat loss in the inner liner. The outer box of inner liner and the door liner mechanism greatly reduce the heat out of the inner cavity.
3) Internal structure of the box: the heat of the electric heater placed on the back of the box is discharged forward through the side air ducts, and then sucked in by the fan with good performance on the back after passing through the dry matter, forming a reasonable air duct, which can make the hot air fully convection, so that the temperature inside the box is uniform to a large extent.
4) Observation window: the box door with a glass observation window, you can observe the box test status;
5) Adjustable new air inlet: control the amount of air in and out of the box, the back of the box is equipped with a closed or adjustable exhaust volume of the exhaust port to play the role of air exchange.
6) Sensor: A class PT100 platinum resistance;
Heating mode: nickel-chromium alloy electric heater
Parameters
Model |
GRX -9023A |
GRX -9053A |
GRX-9070A |
GRX-9123A |
GRX -9203A |
Power supply |
220V 50HZ |
||||
Input Power |
600W |
900W |
1150W |
1600W |
2100W |
Temperature Control |
RT+10~ 250℃ |
||||
Temperature Resolution |
0.1℃ |
||||
Temperature Fluctuation |
± 0.5℃ |
||||
Chamber Size(mm)W × D × H |
300×300×270 |
420×350×350 |
400×350×500 |
550×350×550 |
600×550×600 |
Appearance size(mm)W×D×H |
500×450×440 |
710×520×520 |
600×550×755 |
840×530×730 |
890×730×780 |
Shelf |
2pieces,removable shelf. |
||||
Timing Range |
1-9999min |