The Visual Window Reactor is a commonly used experimental equipment for experiments in the fields of chemistry, biology and medicine. At the end of the experiment, the reactor needs to be disassembled for cleaning and maintenance. This article will introduce you to the detailed disassembly tutorial.
Ⅰ. Preparation
1. Make sure that the experiment has been completed and there is no residual material in the reactor.
2. Close all the valves of the reactor to ensure that the system is not under pressure.
3. Wear protective equipment, such as gloves, goggles and so on.
4. Prepare dismantling tools, such as spanners, screwdrivers, etc.
Ⅱ. Disassembly steps
1. Disassemble the window of the reactor: firstly, loosen the fastening nut on the window, and then gently take down the window. Be careful not to exert too much force, so as not to damage the window glass.
2. Disassemble the stirrer of the kettle: loosen the fastening nut on the stirrer, and then take down the stirrer. Pay attention to check whether the stirring shaft is worn or damaged, and replace it in time if necessary.
3. Disassemble the heater of the reactor: loosen the fastening nut on the heater, and then remove the heater. Check whether the heater is worn or damaged, and replace it in time if necessary.
4. Disassemble the inlet and outlet pipes of the kettle: loosen the fastening nuts on the inlet and outlet pipes, and then remove the pipes. Check whether the pipeline is worn or damaged, and replace it in time if necessary.
5. Disassemble the stand of the reactor: loosen the fastening nuts on the stand, and then take down the stand. Pay attention to check whether the bracket is deformed or damaged, if necessary, replace it in time.
6. Disassemble the main body of the reactor: loosen the fastening nut on the main body, and then take down the main body. Pay attention to check whether there is any residual material inside the main body, and clean it if necessary.
Ⅲ. Cleaning and maintenance
1. Clean all parts of the reactor, such as the main body, bracket, pipeline, etc., use neutral cleaner and soft cloth to wipe clean. Be careful not to use corrosive cleaning agents, so as not to damage the equipment.
2. Clean the window glass, use a soft cloth to wipe clean. If there are stubborn stains, use a small amount of alcohol to wipe.
3. Clean the stirring shaft and stirrer, use a soft cloth to wipe clean. If there are stubborn stains, use a small amount of alcohol to wipe.
4. Clean the heater and wipe it clean with a soft cloth. If there are stubborn stains, use a small amount of alcohol to wipe.
5. Check whether there is any wear and tear or damage to the parts, and replace them in time if necessary.
6. Maintain the reactor regularly to prolong the service life of the equipment.
Through the above steps, you can easily complete the disassembly of the window reactor after the experiment. During the disassembly process, please pay attention to safety to avoid damage to the equipment. At the same time, clean and maintain the reactor regularly to ensure the normal operation and service life of the equipment.
Post time: Aug-23-2024